eCatHub
All catalogs

Farui FRTS-5660 · Cone Calorimeter

Cone Calorimeter · Editable product manual

Published by: lyping · Reuse license: All rights reserved

The interface language does not change the original catalog content.

View PDF · Download PDF

Cover

Farui cover brand

FRTS-5660

Cone Calorimeter

Cone Calorimeter

OXYGEN CONSUMPTION / MATERIAL RESEARCH

Resolve ignition, heat release and mass loss over time.

Study small-scale material behaviour under controlled radiant exposure. Cone calorimetry links ignition, heat release, smoke and mass change, helping development teams compare coatings, thicknesses and formulations under a defined thermal condition.

Principle

A conical heater exposes the specimen to a selected heat flux.

System

Radiant heater, specimen holder, load measurement, collection hood, exhaust measurement, gas analysis and acquisition software.

Application

Building materials, rail-interior materials and polymer research.

Original equipment photograph. Appearance only.

Original equipment photograph. Appearance only.

Sichuan Farui Testing Equipment Co., Ltd.

Product purpose and selection

VI / original brand mark

FRT…

Pro…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

01 / PRODUCT / APPLICATION

Product purpose and selection

Study small-scale material behaviour under controlled radiant exposure. Cone calorimetry links ignition, heat release, smoke and mass change, helping development teams compare coatings, thicknesses and formulations under a defined thermal condition.

Original equipment photograph. Appearance only.

Original equipment photograph. Appearance only.

Measurement principle

VI / original brand mark

FRT…

Mea…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

OXYGEN CONSUMPTION

Measurement principle

A conical heater exposes the specimen to a selected heat flux.

Measurement principle

A conical heater exposes the specimen to a selected heat flux. Combustion products enter an exhaust measurement section; oxygen concentration and exhaust flow support calorimetry, alongside weighing and optical smoke measurements.

Original equipment photograph. Appearance only.

Original equipment photograph. Appearance only.

Use in the laboratory

Radiant heater, specimen holder, load measurement, collection hood, exhaust measurement, gas analysis and acquisition software.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

Specimens and construction

VI / original brand mark

FRT…

Spe…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

SPECIMEN & EXPOSURE

Specimens and construction

Building materials, rail-interior materials and polymer research.

01

Specimens and construction

Building materials, rail-interior materials and polymer research. Optional gas analysis is selected for the study rather than assumed in the base equipment.

02

Use in the laboratory

Record heat flux, ignition mode, exposed area and edge wrapping. Check oxygen, flow and mass calibration, and use a common time reference for HRR, THR, ignition and mass change.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

Calibration and verification

VI / original brand mark

FRT…

Cal…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

CALIBRATION & QUALITY

Calibration and verification

Radiant heater, specimen holder, load measurement, collection hood, exhaust measurement, gas analysis and acquisition software.

01

Calibration and verification

Radiant heater, specimen holder, load measurement, collection hood, exhaust measurement, gas analysis and acquisition software.

02

Use in the laboratory

Record heat flux, ignition mode, exposed area and edge wrapping. Check oxygen, flow and mass calibration, and use a common time reference for HRR, THR, ignition and mass change.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

Test sequence

VI / original brand mark

FRT…

Tes…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

TEST WORKFLOW

Test sequence

A conical heater exposes the specimen to a selected heat flux.

Test sequence

A conical heater exposes the specimen to a selected heat flux. Combustion products enter an exhaust measurement section; oxygen concentration and exhaust flow support calorimetry, alongside weighing and optical smoke measurements.

Original equipment photograph. Appearance only.

Original equipment photograph. Appearance only.

Use in the laboratory

Record heat flux, ignition mode, exposed area and edge wrapping. Check oxygen, flow and mass calibration, and use a common time reference for HRR, THR, ignition and mass change.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

Calculation and reported quantities

VI / original brand mark

FRT…

Cal…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

MEASUREMENTS & CALCULATIONS

Calculation and reported quantities

ISO 5660-1 and ASTM E1354 address calorimetry under controlled radiant exposure.

01

Calculation and reported quantities

ISO 5660-1 and ASTM E1354 address calorimetry under controlled radiant exposure. Heat flux, orientation, backing and edge restraint affect results. Sector-specific requirements still determine specimen preparation and acceptance criteria.

02

Use in the laboratory

Record heat flux, ignition mode, exposed area and edge wrapping. Check oxygen, flow and mass calibration, and use a common time reference for HRR, THR, ignition and mass change.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

Hardware arrangement

VI / original brand mark

FRT…

Har…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

HARDWARE & CONFIGURATION

Hardware arrangement

Radiant heater, specimen holder, load measurement, collection hood, exhaust measurement, gas analysis and acquisition software.

01

Hardware arrangement

Radiant heater, specimen holder, load measurement, collection hood, exhaust measurement, gas analysis and acquisition software.

02

Use in the laboratory

Building materials, rail-interior materials and polymer research. Optional gas analysis is selected for the study rather than assumed in the base equipment.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

Control software and records

VI / original brand mark

FRT…

Con…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

DATA & SOFTWARE

Control software and records

Record heat flux, ignition mode, exposed area and edge wrapping.

What the screenshots show

These screenshots are original captures from the reviewed Chinese edition. They illustrate operating, recording or reporting functions available in that software. Displayed readings remain examples from the captured session.

How to read them

Record heat flux, ignition mode, exposed area and edge wrapping. Check oxygen, flow and mass calibration, and use a common time reference for HRR, THR, ignition and mass change.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

Intended application

VI / original brand mark

FRT…

Int…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

APPLICATION & INTERPRETATION

Intended application

Building materials, rail-interior materials and polymer research.

Intended application

Building materials, rail-interior materials and polymer research. Optional gas analysis is selected for the study rather than assumed in the base equipment.

Use in the laboratory

ISO 5660-1 and ASTM E1354 address calorimetry under controlled radiant exposure. Heat flux, orientation, backing and edge restraint affect results. Sector-specific requirements still determine specimen preparation and acceptance criteria.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

High-tech enterprise

VI / original brand mark

FRT…

Hig…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

10 / COMPANY

High-tech enterprise

Sichuan Farui Testing Equipment Co., Ltd. holds a High-tech Enterprise certificate. Its work covers fire-protection and material fire-test equipment, measurement and control software, and laboratory system integration.

Original High-tech Enterprise certificate. Dates and identifiers follow the certificate as issued.

Original High-tech Enterprise certificate. Dates and identifiers follow the certificate as issued.

Certificate number

GR202551000122

Issue date

2025.12.02

Stated validity

Three years

Issue date and validity are shown as stated on the certificate.

Quality management system

VI / original brand mark

FRT…

Qua…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

11 / COMPANY

Quality management system

From technical requirements through on-site use, Farui organises instrument development, assembly and service within the certified management-system scope, connecting requirement confirmation, technical implementation and project delivery.

Original quality-management-system certificate. This is a company-system certificate, not product certification.

Original quality-management-system certificate. This is a company-system certificate, not product certification.

Certified standard

GB/T 19001-2016 / ISO 9001:2015

Certified scope

Research, assembly and service of industrial automatic-control system instruments

Registration number

30924Q0210R0S

Stated validity on the certificate

2024.06.06 — 2027.06.05

This page records the company management-system certificate. Coverage and current standing remain those registered by the certification body.

Industry participation

VI / original brand mark

FRT…

Ind…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

12 / COMPANY

Industry participation

As a senior member of the Smart Laboratory Professional Committee of the China Association for Standardization, Farui follows test standards and smart-laboratory practice, connecting industry exchange with instrument design, measurement and technical service.

Original senior-membership certificate of the Smart Laboratory Professional Committee.

Original senior-membership certificate of the Smart Laboratory Professional Committee.

Membership and organisation

Senior member, Smart Laboratory Professional Committee, China Association for Standardization

Issue date

2026.07.21

Stated validity on the certificate

2027.07.20

Membership is shown as registered on the original certificate and its stated validity date.

Research and standards participation

VI / original brand mark

FRT…

Res…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

13 / COMPANY

Research and standards participation

Around flame retardancy, fire protection and measurement systems, Farui continues to accumulate instrument-design, automatic-control and test-method experience, using research and standards participation in technical discussion and system design for complex tests.

8

Invention patents (count)

4

Utility models (count)

4

GB/T participation (count)

From method to apparatus

Test conditions, measured quantities and use cases are translated into configuration options, with the test method as the starting point for technical discussion.

From signal to record

Data acquisition, control software and combined systems are organised so that original signals, operating conditions and reported results remain corresponding.

Figures follow the April 2026 company introduction. Patent applications are not distinguished from granted patents. Participation lists follow the corresponding documents.

Contact Farui

FRT…

Contact Farui

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

CONTACT / FIRETS

Contact Farui

Discuss selection against the intended method, material and specimen form, measurement and reporting needs. Supply configuration and laboratory conditions follow the technical documents confirmed by both parties.

From the test need to the equipment configuration

Product selection / technical exchange Project configuration / service enquiry

Contact us on WeChat

Connect on WeChat

Sichuan Farui Testing Equipment Co., Ltd.

18281912988 / lyping@firets.com

58 Zhongjing Road, Youxian District, Mianyang, Sichuan, China

www.firets.com

Official references

Cited source

Cited source

ISO 5660-1:2015/Amd 1:2019

Cited method source

Cited source

Cited source