Cover

Farui cover brand

FRTS-60754

Cable Combustion Gas Acidity and Conductivity Apparatus

Cable Combustion Gas Acidity and Conductivity Apparatus

CABLE MATERIALS / GAS ANALYSIS

Collect and analyse gases released by cable materials.

Generate and collect combustion gases from non-metallic cable materials for the selected chemical analysis. Different parts of the method address different analytical tasks and require the corresponding instruments and consumables.

Principle

A prepared sample is heated in a tube furnace.

System

Tube furnace, quartz tube, sample boats, airflow control and absorption vessels, with method-specific analytical instruments and reagents.

Application

Cable-material gas analysis and investigation of acid-gas and potential corrosivity characteristics.

Catalogue illustration, not a live product photograph.

Catalogue illustration, not a live product photograph.

Sichuan Farui Testing Equipment Co., Ltd.

Product purpose and selection

VI / original brand mark

FRT…

Pro…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

01 / PRODUCT / APPLICATION

Product purpose and selection

Generate and collect combustion gases from non-metallic cable materials for the selected chemical analysis. Different parts of the method address different analytical tasks and require the corresponding instruments and consumables.

Catalogue illustration, not a live product photograph.

Catalogue illustration, not a live product photograph.

Measurement Routes

VI / original brand mark

FRT…

Mea…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

MEASUREMENT PRINCIPLES

Measurement Routes

Generate and collect combustion gases from non-metallic cable materials for the selected chemical analysis.

Measurement Routes

Generate and collect combustion gases from non-metallic cable materials for the selected chemical analysis. Different parts of the method address different analytical tasks and require the corresponding instruments and consumables.

Use in the laboratory

Record sample mass, heating programme, airflow and absorption volume. Verify balance, temperature and analytical instruments; retain blanks and reagent conditions.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

Specimens and conditioning

VI / original brand mark

FRT…

Spe…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

SPECIMEN PREPARATION

Specimens and conditioning

Cable-material gas analysis and investigation of acid-gas and potential corrosivity characteristics.

01

Specimens and conditioning

Cable-material gas analysis and investigation of acid-gas and potential corrosivity characteristics.

02

Use in the laboratory

Record sample mass, heating programme, airflow and absorption volume. Verify balance, temperature and analytical instruments; retain blanks and reagent conditions.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

Thermal And Flow

VI / original brand mark

FRT…

The…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

THERMAL AND FLOW CONTROL

Thermal And Flow

Tube furnace, quartz tube, sample boats, airflow control and absorption vessels, with method-specific analytical instruments and reagents.

01

Thermal And Flow

Tube furnace, quartz tube, sample boats, airflow control and absorption vessels, with method-specific analytical instruments and reagents.

02

Use in the laboratory

Cable-material gas analysis and investigation of acid-gas and potential corrosivity characteristics.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

Halogen Workflow

VI / original brand mark

FRT…

Hal…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

HALOGEN ACID WORKFLOW

Halogen Workflow

A prepared sample is heated in a tube furnace.

01

Halogen Workflow

A prepared sample is heated in a tube furnace. Controlled airflow transports the generated gases into an absorption solution, which is then analysed or measured for pH and conductivity as required.

02

Use in the laboratory

Record sample mass, heating programme, airflow and absorption volume. Verify balance, temperature and analytical instruments; retain blanks and reagent conditions.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

Ph Conductivity

VI / original brand mark

FRT…

Ph …

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

PH AND CONDUCTIVITY

Ph Conductivity

Generate and collect combustion gases from non-metallic cable materials for the selected chemical analysis.

Ph Conductivity

Generate and collect combustion gases from non-metallic cable materials for the selected chemical analysis. Different parts of the method address different analytical tasks and require the corresponding instruments and consumables.

Use in the laboratory

Record sample mass, heating programme, airflow and absorption volume. Verify balance, temperature and analytical instruments; retain blanks and reagent conditions.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

Calculation Judgement

VI / original brand mark

FRT…

Cal…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

RESULTS AND INTERPRETATION

Calculation Judgement

IEC 60754-1 and -2 have different analytical objectives.

01

Calculation Judgement

IEC 60754-1 and -2 have different analytical objectives. Part 2 uses solution pH and conductivity to assess potential corrosivity. These results are distinct from smoke density and do not replace human-exposure toxicity assessment.

02

Use in the laboratory

Record sample mass, heating programme, airflow and absorption volume. Verify balance, temperature and analytical instruments; retain blanks and reagent conditions.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

Supply configuration

VI / original brand mark

FRT…

Sup…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

CONFIGURATION AND ACCEPTANCE

Supply configuration

Record sample mass, heating programme, airflow and absorption volume.

Supply configuration

Record sample mass, heating programme, airflow and absorption volume. Verify balance, temperature and analytical instruments; retain blanks and reagent conditions.

Use in the laboratory

Cable-material gas analysis and investigation of acid-gas and potential corrosivity characteristics.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

Software Report

VI / original brand mark

FRT…

Sof…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

DATA AND REPORTING

Software Report

Record sample mass, heating programme, airflow and absorption volume.

What the screenshots show

These screenshots are original captures from the reviewed Chinese edition. They illustrate operating, recording or reporting functions available in that software. Displayed readings remain examples from the captured session.

How to read them

Record sample mass, heating programme, airflow and absorption volume. Verify balance, temperature and analytical instruments; retain blanks and reagent conditions.

English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.

High-tech enterprise

VI / original brand mark

FRT…

Hig…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

10 / COMPANY

High-tech enterprise

Sichuan Farui Testing Equipment Co., Ltd. holds a High-tech Enterprise certificate. Its work covers fire-protection and material fire-test equipment, measurement and control software, and laboratory system integration.

Original High-tech Enterprise certificate. Dates and identifiers follow the certificate as issued.

Original High-tech Enterprise certificate. Dates and identifiers follow the certificate as issued.

Certificate number

GR202551000122

Issue date

2025.12.02

Stated validity

Three years

Issue date and validity are shown as stated on the certificate.

Quality management system

VI / original brand mark

FRT…

Qua…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

11 / COMPANY

Quality management system

From technical requirements through on-site use, Farui organises instrument development, assembly and service within the certified management-system scope, connecting requirement confirmation, technical implementation and project delivery.

Original quality-management-system certificate. This is a company-system certificate, not product certification.

Original quality-management-system certificate. This is a company-system certificate, not product certification.

Certified standard

GB/T 19001-2016 / ISO 9001:2015

Certified scope

Research, assembly and service of industrial automatic-control system instruments

Registration number

30924Q0210R0S

Stated validity on the certificate

2024.06.06 — 2027.06.05

This page records the company management-system certificate. Coverage and current standing remain those registered by the certification body.

Industry participation

VI / original brand mark

FRT…

Ind…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

12 / COMPANY

Industry participation

As a senior member of the Smart Laboratory Professional Committee of the China Association for Standardization, Farui follows test standards and smart-laboratory practice, connecting industry exchange with instrument design, measurement and technical service.

Original senior-membership certificate of the Smart Laboratory Professional Committee.

Original senior-membership certificate of the Smart Laboratory Professional Committee.

Membership and organisation

Senior member, Smart Laboratory Professional Committee, China Association for Standardization

Issue date

2026.07.21

Stated validity on the certificate

2027.07.20

Membership is shown as registered on the original certificate and its stated validity date.

Research and standards participation

VI / original brand mark

FRT…

Res…

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

13 / COMPANY

Research and standards participation

Around flame retardancy, fire protection and measurement systems, Farui continues to accumulate instrument-design, automatic-control and test-method experience, using research and standards participation in technical discussion and system design for complex tests.

8

Invention patents (count)

4

Utility models (count)

4

GB/T participation (count)

From method to apparatus

Test conditions, measured quantities and use cases are translated into configuration options, with the test method as the starting point for technical discussion.

From signal to record

Data acquisition, control software and combined systems are organised so that original signals, operating conditions and reported results remain corresponding.

Figures follow the April 2026 company introduction. Patent applications are not distinguished from granted patents. Participation lists follow the corresponding documents.

Contact Farui

FRT…

Contact Farui

FARUI FIRETS

FIRETS.COM

{{page}} / {{pages}}

CONTACT / FIRETS

Contact Farui

Discuss selection against the intended method, material and specimen form, measurement and reporting needs. Supply configuration and laboratory conditions follow the technical documents confirmed by both parties.

From the test need to the equipment configuration

Product selection / technical exchange Project configuration / service enquiry

Contact us on WeChat

Connect on WeChat

Sichuan Farui Testing Equipment Co., Ltd.

18281912988 / lyping@firets.com

58 Zhongjing Road, Youxian District, Mianyang, Sichuan, China

www.firets.com

Fontes oficiais

Cited source

Cited source

Cited source

Cited source

Cited method source

Cited method source