Build a measurement system
NI CompactDAQ
01 / 12
Independent series guide
NI CompactDAQ · Measurement systems
An independent 12-page guide to CompactDAQ chassis, C Series measurements, software, synchronization and project selection.
cDAQ-9173 · © NI
© NI · cDAQ-9173
Sensors → modules → chassis → software
Define the decision the measurement supports
Keep model names unchanged
eCatHub · Independent series guide
01
From sensor to useful data
NI CompactDAQ
02 / 12
From sensor to useful data
Treat the signal path as a chain: sensor, input conditioning, conversion, timing, transfer and analysis. Write down the physical quantity and the required result before selecting a module or software interface.
cDAQ-9183 · laboratory · © NI
© NI · cDAQ-9183 · laboratory
Review checklist
01
Physical quantity and units
02
Expected range and signal bandwidth
03
Where the result will be consumed
eCatHub · Independent series guide
02
Chassis portfolio
NI CompactDAQ
03 / 12
Chassis portfolio
The chassis determines connectivity, available slots and system timing. Compare a small USB setup with an Ethernet installation near distributed sensors. Reserve capacity for planned channels rather than selecting on slot count alone.
cDAQ-9170 · © NI
© NI · cDAQ-9170
cDAQ-9173 · © NI
© NI · cDAQ-9173
cDAQ-9187 · © NI
© NI · cDAQ-9187
| cDAQ-9170 | 1-slot USB-C chassis |
|---|---|
| cDAQ-9173 | 4-slot USB-C chassis |
| cDAQ-9187 | 8-slot Ethernet chassis |
| C Series | Choose by measurement type and compatibility |
eCatHub · Independent series guide
03
Match the measurement module
NI CompactDAQ
04 / 12
Match the measurement module
C Series includes different measurement and interface families. Temperature, strain and dynamic signals require different input characteristics. A connector that fits is not enough: check sensor excitation, range, isolation and the exact supported configuration.
NI-9223 · C Series · © NI
© NI · NI-9223 · C Series
Review checklist
01
Voltage / current / temperature
02
Strain / sound / vibration
03
Digital I/O and bus interfaces
eCatHub · Independent series guide
04
Timing and synchronization
NI CompactDAQ
05 / 12
Timing and synchronization
A common start event and a common time reference solve different problems. Specify acceptable alignment between signals, then verify the timing behavior of the selected chassis, module combination, driver and acquisition rates.
cDAQ-9187 · © NI
© NI · cDAQ-9187
Review checklist
01
Start trigger versus shared time
02
Single chassis versus multiple chassis
03
Verify behavior at the intended sample rates
eCatHub · Independent series guide
05
Choose the software workflow
NI CompactDAQ
06 / 12
Choose the software workflow
NI-DAQmx supports programmed acquisition workflows; FlexLogger offers a configuration-oriented route. Decide who maintains the application, how results are named and where data is stored. Bus interfaces may require their own drivers.
LabVIEW · CompactDAQ · © NI
© NI · LabVIEW · CompactDAQ
Review checklist
01
Programming versus configuration
02
File naming and channel metadata
03
Driver and operating-system compatibility
eCatHub · Independent series guide
06
Plan the physical installation
NI CompactDAQ
07 / 12
Plan the physical installation
Include cables, terminals, power, mounting and the host in the system plan. Separate the electrical design from the data workflow, then review both together. Confirm operating limits for the chosen parts rather than applying a family-wide rating.
CompactDAQ · DIN · © NI
© NI · CompactDAQ · DIN
Review checklist
01
Power and grounding plan
02
Cable identification and strain relief
03
Access for maintenance and replacement
eCatHub · Independent series guide
07
Example: mixed-sensor test bench
NI CompactDAQ
08 / 12
Example: mixed-sensor test bench
Illustrative brief: observe temperature and vibration during a motor test. Keep slow thermal trends and faster dynamic records distinguishable, while documenting how they are related in time. This is a planning example, not a validated hardware configuration.
cDAQ-9183 · laboratory · © NI
© NI · cDAQ-9183 · laboratory
Review checklist
01
Thermal channel list
02
Dynamic channel list
03
A documented time relationship
eCatHub · Independent series guide
08
A practical selection sequence
NI CompactDAQ
09 / 12
A practical selection sequence
Start with a channel inventory. Convert each sensor requirement into a module shortlist, then check chassis and software compatibility. Finish with accessories and a repeatable acceptance test before freezing the purchasing list.
cDAQ-9173 · © NI
© NI · cDAQ-9173
Review checklist
01
Inventory → shortlist → compatibility
02
Accessories → acceptance test
03
Record unresolved supplier questions
eCatHub · Independent series guide
09
Commissioning and data quality
NI CompactDAQ
10 / 12
Commissioning and data quality
Validate one channel before scaling the system. Record raw values, engineering units, timestamps and test conditions. Exercise a missing-sensor or disconnected-host case and document how the application reports incomplete data.
NI-9223 · C Series · © NI
© NI · NI-9223 · C Series
Review checklist
01
Baseline reading and units
02
Timestamp and file continuity
03
Disconnect and recovery observations
eCatHub · Independent series guide
10
Prepare a complete project brief
NI CompactDAQ
11 / 12
Prepare a complete project brief
A useful project brief records assumptions, unresolved questions and acceptance criteria as well as products. Duplicate this page and replace the prompts with your own requirements; keep the source document revision beside each confirmed decision.
Editable project worksheet
01
Signal, range and channel count
02
Timing, environment and storage
03
Owner, review date and acceptance test
Review checklist
| Signal, range and channel count | Record for your project |
|---|---|
| Timing, environment and storage | Record for your project |
| Owner, review date and acceptance test | Record for your project |
eCatHub · Independent series guide
11
Sources and reuse
NI CompactDAQ
12 / 12
Sources and reuse
The linked manufacturer pages are the reference for current product specifications. This publication contains original summaries and illustrative layouts, not reproduced manuals or product photographs. Translations are editorial examples and have not been approved by NI.
Official references · 2026-09-28
| NI-01 | https://www.ni.com/en/shop/compactdaq.html |
|---|---|
| NI-02 | https://www.ni.com/zh-cn/shop/compactdaq.html |
| NI-03 | https://www.ni.com/en/shop/compactdaq/compactdaq-modules.html |
| NI-04 | https://www.ni.com/en/support/documentation/supplemental/21/time-based-synchronization-of-analog-input-c-series-modules-with.html |
| NI-05 | https://www.ni.com/pdf/product-flyers/compactdaq-systems.pdf |
An eCatHub editorial demo, not an official manufacturer catalogue. Original text and diagrams: CC BY 4.0. Product names belong to their owners. Confirm specifications and compatibility in the linked official documents. Photographs and product illustrations © NI / Siemens; excluded from CC BY 4.0. See official references for image sources.
eCatHub · Independent series guide
12
Official references
NI-01 · CompactDAQ systems — official series overview
NI-02 · CompactDAQ 系统 — 官方中文产品线资料
NI-03 · C Series modules — official product families
NI-04 · Time-based synchronization of C Series analog inputs
NI-05 · CompactDAQ System Flyer — manufacturer PDF, external reading