Cover
EQIO
RMC-6417
PRODUCT MANUAL
4U Seven-Slot CompactPCI Rack Computing Platform
Rack-mount CPCI platform · Multi-channel…
Application illustration (not a product photo); shipped units may differ.
Measurement and control, made easy.
Easy · Quick · Input · Output
EQIO.COM
Overview
EQIO
{{chapter}}
EQIO · RMC-6417 Product Manual
{{page}} / {{pages}}
01 OVERVIEW
4U Seven-Slot CompactPCI Rack Computing Platform
Rack-mount CPCI platform · Multi-channel data acquisition · Multi board measurement and control · Industrial automation · CompactPCI
RMC-6417 uses 1 system slot and 6 expansion slot 6U CompactPCI backplane, configured with dual 250W AC power and hot-swap fans module, facilitates multi I/O board integrates and module maintenance. Dual all-aluminium-alloy layer housing settings 2 independent power location, front panel provides USB, switch and run indicator. Can combination compute, acquisition and communications module, suited to rack-mount equipment bring-up and multi-channel test, modular card-cage facilitates adjust system function.
4U Seven-Slot CompactPCI Rack Computing Platform product photo
Application illustration (not a product photo); shipped units may differ.
Key features
4U dual all-aluminium-alloy layer chassis 1 system slot and 6 expansion slot Dual 250W AC power module
Hot-swap fans and side airflow Front panel USB and run indicator
Functions
EQIO
{{chapter}}
EQIO · RMC-6417 Product Manual
{{page}} / {{pages}}
02 FUNCTIONS
Functions and engineering value
7-slot modular system space
4U dual all-aluminium-alloy layer chassis configured with 6U 7-slot backplane, 1 system slot and 6 expansion slot used for combination compute, acquisition and communications board card. Relatively multi expansion location facilitates per task arrangement module, but bus resources, board between coordination and performance still by selected controller and function card determine.
Dual power location and power configured with
Chassis provides 2 3U 8HP power slot and configured with 2 250W AC power, facilitates organize system power. Published data not stated all stream, redundant, hot-swap or can combined and output conditions, therefore power mode, each channel capacity and fault processing should per power solution single independent confirm.
Side cooling and maintenance operation
Left in, right out airflow together with hot-swap fans module, front panel provides USB, switch and power indicator, front rear handle auxiliary maintenance. Deployment when needed leave side ventilation and module removable space, and controller, rear I/O and external wiring harness one and include cabinet layout.
The functional notes explain the product’s role from published configuration. Optional functions, software and peripherals follow the project definition. Chip capability is not the same as implemented I/O.
Architecture
EQIO
{{chapter}}
EQIO · RMC-6417 Product Manual
{{page}} / {{pages}}
03 ARCHITECTURE
Product functional architecture
Functional block diagram
From published specification illustrative functional grouping, does not show internal circuits, on-board bus or signal routing; I/O direction actual protocol shall prevail. 2 power power mode delivery wiring shall prevail, not indicates already confirm redundant or hot-swap.
Platform and I/O
This product 6U 7-slot CompactPCI rack platform, compute resources from system slot in system controller provides. 3rd-generation Intel Core i7 only controller configured with reference, specific CPU, memory and operating system required confirm; dual 250W power also not can directly derive redundant or total can used 500W.
Reading the diagram Solid lines show published functional relationships, not on-board buses, bridge chips or connector pins. Optional controllers, radios, storage and software follow the configuration and interface files.
SPECIFICATIONS
EQIO
{{chapter}}
EQIO · RMC-6417 Product Manual
{{page}} / {{pages}}
04 SPECIFICATIONS
Technical specifications
Compiled from published product data. Batch, I/O and environmental ratings follow the order confirmation.
Mechanics and system
| Structure | All-aluminium dual layer chassis design |
|---|---|
| Front panel | Has power LED power switch, USB I/O |
| Handle | Front panel both sides chassis handle, rear panel fan module handle |
| Cooling | Left in, right out airflow design, hot-swap fans module (power 12W, fan noise≤60DB) |
| Process | Front rear aluminium alloy panel brushed anodized process, surface dual layer paint process |
I/O and expansion
| Backplane | 6U 7C integrated backplane, 1 6U system slot and 6 6U expansion slot, 2 3U 8HP power slot |
|---|---|
| Backplane bus | CompactPCI®bus, 64bit/33MHz or 66MHz |
| Controller configuration | 6U CompactPCI® 3rd-generation Intel®Core™i7 processor system controller |
| Standard interfaces | Main board provides USB, Ethernet port, VGA display etc.standard interfaces |
Mechanical specifications and system requirements
| Dimensions / weight | 385.8mm × 482.6mm × 177mm (not including handle), weight≤13.0kg (not including main card) |
|---|---|
| Environmental ratings | Operating temperature: 0℃~60℃, -20℃~70℃ (industrial grade), -40℃~80℃ (military-grade), storage temperature: -20℃~85℃ |
| Power configured with | 250W AC power; 2 power module |
Applications
EQIO
{{chapter}}
EQIO · RMC-6417 Product Manual
{{page}} / {{pages}}
05 APPLICATIONS
From product capability to applications
Multi-channel measurement and control rack
6 6U expansion location can combination acquisition, communications and control board card, system main card responsible for application run and data organize. Different module sampling, synchronous or trigger capability must separately check, 7-slot structure only provides hosts conditions, not represent pre-installed type measurement channel or instrument function.
Multi board equipment bring-up
Can target I/O required function card centralized to the same chassis, via main card and rear I/O connect external equipment, and uses front panel I/O completes maintenance. Relatively multi board together run when note bus bandwidth, power consumption and airflow assign, avoid only per single card metrics determine system behaviour.
Modular industrial control cabinet
4U rack structure suited to place fixed control cabinet, per task selection compute and I/O module, power and fan location facilitates service planning. Dual power whether handles redundant or branch power requires stated design, maintenance procedure must and actual power wiring and power-off requirements consistent.
Integration checks
| Slot position planning | Confirm 1 system slot and 6 expansion slot main card, function card and rear I/O configured with. |
|---|---|
| Dual power method | 2 250W not automatic represent 500W can used or redundant, confirm branch, all stream and fault. |
| Air stream and maintenance | Left in, right out airflow and fan removable direction required and cabinet layout match. |
| Version selection | Different operating temperature version respectively confirm, complete set main card and function card must meets the same target. |
Configuration
EQIO
{{chapter}}
EQIO · RMC-6417 Product Manual
{{page}} / {{pages}}
06 CONFIGURATION
Configuration, options and selection
Configuration
Can paired with 6U CompactPCI controller and rear I/O board, provides different operating temperature version.
| Temperature version | 0~60℃ / -20~70℃ / -40~80℃ |
|---|
Selection guide
| Order confirmation | Batch, I/O and environmental ratings follow the order confirmation |
|---|---|
| Published data | Compiled from published product data; EQIO provides selection and system integration |
| Configuration talk | Share the application, I/O count, environment and software so a configuration can be proposed |
Request a quotation and selection support
Email lyping@eqio.com Phone +86 182 8191 2988 Web eqio.com
Brand
EQIO · RMC-6417 Product Manual
{{page}} / {{pages}}
EQIO Easy Quick Input Output
BRAND
Measurement and control, made easy.
EQIO product family concept
EQIO product family · concept rendering
Brand story
EQIO builds measurement and control products and systems. The name stands for Easy Quick Input Output: Easy is a clear structure that is quick to learn, Quick is a direct path to efficient delivery, and Input / Output is every link between the device under test and the control system. The soft single-cycle wave inside the Q links the brand to signals, acquisition and I/O. “Measurement and control, made easy” is our promise for every selection, integration and delivery.
What we do
| Products | Data acquisition, test instruments, control and I/O, modular platforms, software, cables |
|---|---|
| Systems | Configured to the measurand, channels, accuracy and software, from design to commissioning |
| Support | Selection advice, training, maintenance and calibration |
How we deliver
| Requirements | |
|---|---|
| Solution design | |
| Build & integration | |
| Factory test | |
| Delivery & training | |
| Ongoing support |
Email lyping@eqio.com Phone +86 182 8191 2988 Web EQIO.COM