Cover
EQIO
RMC-2604
PRODUCT MANUAL
2U Four-Slot CompactPCI Rack Platform with Hot-Swap Fans
Rack-mount CPCI platform · Industrial au…
Application illustration (not a product photo); shipped units may differ.
Measurement and control, made easy.
Easy · Quick · Input · Output
EQIO.COM
Overview
EQIO
{{chapter}}
EQIO · RMC-2604 Product Manual
{{page}} / {{pages}}
01 OVERVIEW
2U Four-Slot CompactPCI Rack Platform with Hot-Swap Fans
Rack-mount CPCI platform · Industrial automation · Rack measurement and control · Equipment matching · CompactPCI
RMC-2604 uses 6U 4-slot CompactPCI backplane, provides 1 system slot and 3 expansion slot, integrates 250W AC power and hot-swap fans module, suited used for compact rack in multi board measurement and control system integration. Left in, right out airflow and independent power slot facilitates organize board cooling and power, front panel provides switch and run indicator. Can combined with system controller and rear I/O board connect measurement and control peripherals, used for cabinet internal data acquisition, communications and automation control.
2U Four-Slot CompactPCI Rack Platform with Hot-Swap Fans product photo
Application illustration (not a product photo); shipped units may differ.
Key features
2U height, 4-slot 6U CompactPCI backplane 1 system slot and 3 expansion slot 250W AC power module
Left in, right out airflow Hot-swap fans module
Functions
EQIO
{{chapter}}
EQIO · RMC-2604 Product Manual
{{page}} / {{pages}}
02 FUNCTIONS
Functions and engineering value
Compact rack board hosts
2U chassis internal configured with 6U 4-slot CompactPCI backplane, 1 system slot and 3 expansion slot used for combination controller and I/O board. Additional has independent 3U 8HP power slot, suited to cabinet in layout small scale modular system, compute and measurement function must follow selected board confirm.
Side airflow and module maintenance
Left in, right out airflow together with hot-swap fans module, front rear handle facilitates arrangement chassis and fan maintenance operation. Source data lists 12W fan power and not high to 60dB noise conditions, cabinet installation required retain side ventilation space, cooling capability must still per actual board load verify against.
Power and rear I/O matching
Platform configured with 1 250W AC power, system controller solution reference 6U 3rd-generation Intel Core i7 board, USB, network and VGA from matching rear I/O provides. Controller and rear I/O should be treated as system configured with confirm, 250W power capability also requires combined with each voltage rail and board requirement evaluate.
The functional notes explain the product’s role from published configuration. Optional functions, software and peripherals follow the project definition. Chip capability is not the same as implemented I/O.
Architecture
EQIO
{{chapter}}
EQIO · RMC-2604 Product Manual
{{page}} / {{pages}}
03 ARCHITECTURE
Product functional architecture
Functional block diagram
From published specification illustrative functional grouping, does not show internal circuits, on-board bus or signal routing; I/O direction actual protocol shall prevail. System controller and rear I/O I/O selected configured with shall prevail; hot-swap not etc.same with electrical replacement claim.
Platform and I/O
This product core is 6U 4-slot CompactPCI backplane and 250W power platform. Data gives 3rd-generation Intel Core i7 system controller configured with reference, but not stated specific CPU model or default shipped with the unit range; should controller selected rear supplement CPU, memory and system parameters.
Reading the diagram Solid lines show published functional relationships, not on-board buses, bridge chips or connector pins. Optional controllers, radios, storage and software follow the configuration and interface files.
SPECIFICATIONS
EQIO
{{chapter}}
EQIO · RMC-2604 Product Manual
{{page}} / {{pages}}
04 SPECIFICATIONS
Technical specifications
Compiled from published product data. Batch, I/O and environmental ratings follow the order confirmation.
Mechanics and system
| Front panel | Has power LED power switch, approximately each side 4 screw used for installation and removal front panel |
|---|---|
| Handle | Front panel both sides chassis handle, rear panel fan module handle |
| Cooling | Left in, right out airflow design, hot-swap fans module (power 12W, fan noise≤60DB) |
| Process | Front rear aluminium alloy panel brushed anodized process, surface dual layer paint process |
I/O and expansion
| Backplane | 6U 4C integrated backplane, 1 6U system slot and 3 6U expansion slot, 1 3U 8HP power slot |
|---|---|
| Backplane bus | CompactPCI®bus, 64bit/33MHz or 66MHz |
| Controller configuration | 6U CompactPCI® 3rd-generation Intel®Core™i7 processor system controller |
| Standard interfaces | Main board rear IO board provides USB, Ethernet port, VGA display etc.standard interfaces |
Mechanical specifications and system requirements
| Dimensions / weight | 383mm × 482.6mm × 88mm (not including handle), weight≤8.0kg (not including main card) |
|---|---|
| Environmental ratings | Operating temperature: 0℃~60℃, -20℃~70℃ (industrial grade), -40℃~80℃ (military-grade), storage temperature: -20℃~85℃ |
| Power configured with | 250W AC power; 1 power module |
Applications
EQIO
{{chapter}}
EQIO · RMC-2604 Product Manual
{{page}} / {{pages}}
05 APPLICATIONS
From product capability to applications
Rack-mount equipment measurement and control
Can system slot installation compatible controller, 3 expansion slot configured with acquisition, communications or control board card, forms compact measurement and control node. Rear I/O responsible for corresponding external connect, specific measurement channel, accuracy and real-time processing capability all by selected board and software definition.
Industrial automation matching
2U height suited to cabinet space limited automation system, system controller run application, I/O board attach equipment signal. Deployment when check side air stream and adjacent equipment layout, avoid cabinet baffle or dense routing block airflow, and inspection fully populated power and temperature rise.
Can maintenance modular workstation
Board and fan module respectively organize, facilitates maintenance plan in inspection cooling, power and I/O connect. Hot-swap fans and not automatic represent with electrical replacement allow can, maintenance operation, power isolated and spare compatible conditions should per actual chassis and module note actuation.
Integration checks
| Board matching | Confirm 6U system controller, 3 expansion slot and rear I/O board compatible relationship and shipped with the unit range. |
|---|---|
| Airflow space | Left in, right out airflow required retain side airflow and fan module maintenance space. |
| Power budget | Check 250W power each channel output, boot load and board power consumption. |
| Temperature version | 0–60℃, -20–70℃ or -40–80℃ different version, not automatic combined and. |
Configuration
EQIO
{{chapter}}
EQIO · RMC-2604 Product Manual
{{page}} / {{pages}}
06 CONFIGURATION
Configuration, options and selection
Configuration
Can paired with 6U CompactPCI controller and rear I/O board, provides different operating temperature version.
| Temperature version | 0~60℃ / -20~70℃ / -40~80℃ |
|---|
Selection guide
| Order confirmation | Batch, I/O and environmental ratings follow the order confirmation |
|---|---|
| Published data | Compiled from published product data; EQIO provides selection and system integration |
| Configuration talk | Share the application, I/O count, environment and software so a configuration can be proposed |
Request a quotation and selection support
Email lyping@eqio.com Phone +86 182 8191 2988 Web eqio.com
Brand
EQIO · RMC-2604 Product Manual
{{page}} / {{pages}}
EQIO Easy Quick Input Output
BRAND
Measurement and control, made easy.
EQIO product family concept
EQIO product family · concept rendering
Brand story
EQIO builds measurement and control products and systems. The name stands for Easy Quick Input Output: Easy is a clear structure that is quick to learn, Quick is a direct path to efficient delivery, and Input / Output is every link between the device under test and the control system. The soft single-cycle wave inside the Q links the brand to signals, acquisition and I/O. “Measurement and control, made easy” is our promise for every selection, integration and delivery.
What we do
| Products | Data acquisition, test instruments, control and I/O, modular platforms, software, cables |
|---|---|
| Systems | Configured to the measurand, channels, accuracy and software, from design to commissioning |
| Support | Selection advice, training, maintenance and calibration |
How we deliver
| Requirements | |
|---|---|
| Solution design | |
| Build & integration | |
| Factory test | |
| Delivery & training | |
| Ongoing support |
Email lyping@eqio.com Phone +86 182 8191 2988 Web EQIO.COM