Cover
Farui cover brand
FRTS-2406
Limiting Oxygen Index Apparatus
Limiting Oxygen Index Apparatus
OXYGEN INDEX / AMBIENT-TEMPERATURE TEST
Compare the oxygen concentration needed to sustain burning.
FRTS-2406 supports ambient-temperature oxygen-index testing of plastics, foams and related polymers. Controlled oxygen and nitrogen mixing helps compare formulations, production batches and specimen thickness under defined burning conditions.
Principle
A prepared specimen is held in a combustion column and ignited in a controlled gas mixture.
System
Combustion column, gas mixing and flow control, specimen holders and adjustable ignition equipment.
Application
Polymer development, material comparisons and quality-control studies.
Original equipment photograph. Appearance only.
Original equipment photograph. Appearance only.
Sichuan Farui Testing Equipment Co., Ltd.
Product purpose and selection
VI / original brand mark
FRT…
Pro…
FARUI FIRETS
FIRETS.COM
{{page}} / {{pages}}
01 / PRODUCT / APPLICATION
Product purpose and selection
FRTS-2406 supports ambient-temperature oxygen-index testing of plastics, foams and related polymers. Controlled oxygen and nitrogen mixing helps compare formulations, production batches and specimen thickness under defined burning conditions.
Original equipment photograph. Appearance only.
Original equipment photograph. Appearance only.
Measurement principle
VI / original brand mark
FRT…
Mea…
FARUI FIRETS
FIRETS.COM
{{page}} / {{pages}}
PRINCIPLE & MEASURAND
Measurement principle
A prepared specimen is held in a combustion column and ignited in a controlled gas mixture.
Original equipment photograph. Appearance only.
Original equipment photograph. Appearance only.
Measurement principle
A prepared specimen is held in a combustion column and ignited in a controlled gas mixture. Oxygen concentration is adjusted in accordance with the required burning-time or burning-length criterion.
Use in the laboratory
Combustion column, gas mixing and flow control, specimen holders and adjustable ignition equipment. Holder selection follows specimen form.
English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.
Specimens and conditioning
VI / original brand mark
FRT…
Spe…
FARUI FIRETS
FIRETS.COM
{{page}} / {{pages}}
SPECIMENS & CONDITIONING
Specimens and conditioning
Polymer development, material comparisons and quality-control studies.
Specimens and conditioning
Polymer development, material comparisons and quality-control studies. Keep specimen geometry and conditioning consistent between comparisons.
Use in the laboratory
Record specimen type, conditioning, ignition procedure, concentration sequence, burning time or length and repeat results. Elevated-temperature oxygen-index testing requires a separate configuration.
English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.
Calibration and verification
VI / original brand mark
FRT…
Cal…
FARUI FIRETS
FIRETS.COM
{{page}} / {{pages}}
CALIBRATION & GAS CONTROL
Calibration and verification
Combustion column, gas mixing and flow control, specimen holders and adjustable ignition equipment.
01
Calibration and verification
Combustion column, gas mixing and flow control, specimen holders and adjustable ignition equipment. Holder selection follows specimen form.
02
Use in the laboratory
Record specimen type, conditioning, ignition procedure, concentration sequence, burning time or length and repeat results. Elevated-temperature oxygen-index testing requires a separate configuration.
English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.
Ignition sequence
VI / original brand mark
FRT…
Ign…
FARUI FIRETS
FIRETS.COM
{{page}} / {{pages}}
IGNITION & RESPONSE SEQUENCE
Ignition sequence
A prepared specimen is held in a combustion column and ignited in a controlled gas mixture.
01
Ignition sequence
A prepared specimen is held in a combustion column and ignited in a controlled gas mixture. Oxygen concentration is adjusted in accordance with the required burning-time or burning-length criterion.
02
Use in the laboratory
Record specimen type, conditioning, ignition procedure, concentration sequence, burning time or length and repeat results. Elevated-temperature oxygen-index testing requires a separate configuration.
English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.
Calculation and criteria
VI / original brand mark
FRT…
Cal…
FARUI FIRETS
FIRETS.COM
{{page}} / {{pages}}
CALCULATION & INTERPRETATION
Calculation and criteria
ISO 4589-2 / GB/T 2406.2 define the ambient-temperature method.
01
Calculation and criteria
ISO 4589-2 / GB/T 2406.2 define the ambient-temperature method. GB 8624-2012 includes additional oxygen-index limits for specified wall-insulation foams: 30% for B1 and 26% for B2, together with the applicable classification requirements. These are not universal limits for all plastics.
02
Use in the laboratory
Record specimen type, conditioning, ignition procedure, concentration sequence, burning time or length and repeat results. Elevated-temperature oxygen-index testing requires a separate configuration.
English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.
Data, records and configuration
VI / original brand mark
FRT…
Dat…
FARUI FIRETS
FIRETS.COM
{{page}} / {{pages}}
REAL CONTROLS & DATA RECORDS
Data, records and configuration
Record specimen type, conditioning, ignition procedure, concentration sequence, burning time or length and repeat results.
Data, records and configuration
Record specimen type, conditioning, ignition procedure, concentration sequence, burning time or length and repeat results. Elevated-temperature oxygen-index testing requires a separate configuration.
Original equipment photograph. Appearance only.
Original equipment photograph. Appearance only.
Use in the laboratory
Polymer development, material comparisons and quality-control studies. Keep specimen geometry and conditioning consistent between comparisons.
Data, records and configuration · continued
VI / original brand mark
FRT…
Dat…
FARUI FIRETS
FIRETS.COM
{{page}} / {{pages}}
08 / REAL CONTROLS & DATA RECORDS
Data, records and configuration · continued
Original equipment photograph. Appearance only.
Original equipment photograph. Appearance only.
English edition follows the reviewed Chinese manuscript evidence. Configuration and laboratory conditions follow the technical file confirmed by both parties. Unconfirmed numerical claims from the Chinese edition are not restated here.
High-tech enterprise
VI / original brand mark
FRT…
Hig…
FARUI FIRETS
FIRETS.COM
{{page}} / {{pages}}
09 / COMPANY
High-tech enterprise
Sichuan Farui Testing Equipment Co., Ltd. holds a High-tech Enterprise certificate. Its work covers fire-protection and material fire-test equipment, measurement and control software, and laboratory system integration.
Original High-tech Enterprise certificate. Dates and identifiers follow the certificate as issued.
Original High-tech Enterprise certificate. Dates and identifiers follow the certificate as issued.
Certificate number
GR202551000122
Issue date
2025.12.02
Stated validity
Three years
Issue date and validity are shown as stated on the certificate.
Quality management system
VI / original brand mark
FRT…
Qua…
FARUI FIRETS
FIRETS.COM
{{page}} / {{pages}}
10 / COMPANY
Quality management system
From technical requirements through on-site use, Farui organises instrument development, assembly and service within the certified management-system scope, connecting requirement confirmation, technical implementation and project delivery.
Original quality-management-system certificate. This is a company-system certificate, not product certification.
Original quality-management-system certificate. This is a company-system certificate, not product certification.
Certified standard
GB/T 19001-2016 / ISO 9001:2015
Certified scope
Research, assembly and service of industrial automatic-control system instruments
Registration number
30924Q0210R0S
Stated validity on the certificate
2024.06.06 — 2027.06.05
This page records the company management-system certificate. Coverage and current standing remain those registered by the certification body.
Industry participation
VI / original brand mark
FRT…
Ind…
FARUI FIRETS
FIRETS.COM
{{page}} / {{pages}}
11 / COMPANY
Industry participation
As a senior member of the Smart Laboratory Professional Committee of the China Association for Standardization, Farui follows test standards and smart-laboratory practice, connecting industry exchange with instrument design, measurement and technical service.
Original senior-membership certificate of the Smart Laboratory Professional Committee.
Original senior-membership certificate of the Smart Laboratory Professional Committee.
Membership and organisation
Senior member, Smart Laboratory Professional Committee, China Association for Standardization
Issue date
2026.07.21
Stated validity on the certificate
2027.07.20
Membership is shown as registered on the original certificate and its stated validity date.
Research and standards participation
VI / original brand mark
FRT…
Res…
FARUI FIRETS
FIRETS.COM
{{page}} / {{pages}}
12 / COMPANY
Research and standards participation
Around flame retardancy, fire protection and measurement systems, Farui continues to accumulate instrument-design, automatic-control and test-method experience, using research and standards participation in technical discussion and system design for complex tests.
8
Invention patents (count)
4
Utility models (count)
4
GB/T participation (count)
From method to apparatus
Test conditions, measured quantities and use cases are translated into configuration options, with the test method as the starting point for technical discussion.
From signal to record
Data acquisition, control software and combined systems are organised so that original signals, operating conditions and reported results remain corresponding.
Figures follow the April 2026 company introduction. Patent applications are not distinguished from granted patents. Participation lists follow the corresponding documents.
Contact Farui
FRT…
Contact Farui
FARUI FIRETS
FIRETS.COM
{{page}} / {{pages}}
CONTACT / FIRETS
Contact Farui
Discuss selection against the intended method, material and specimen form, measurement and reporting needs. Supply configuration and laboratory conditions follow the technical documents confirmed by both parties.
From the test need to the equipment configuration
Product selection / technical exchange Project configuration / service enquiry
Contact us on WeChat
Connect on WeChat
Sichuan Farui Testing Equipment Co., Ltd.
18281912988 / lyping@firets.com
58 Zhongjing Road, Youxian District, Mianyang, Sichuan, China
www.firets.com